Fairbanks and Anchorage, Alaska, experience high wintertime ambient levels of carbon monoxide (CO). Emissions from starting automobile engines in cold weather are thought to be a major source of CO. A quantitative procedure for determining startup CO emissions was developed. The startup emissions were measured as a function of soak time at several low ambient temperatures. The performance of engine preheaters in reducing the startup CO at the various soak times and temperatures was estimated. The data scatter was too great to draw any firm conclusions; however, the length of cold-soak time appeared to have a stronger effect on cold-start CO emissions than did soak temperatures (0 to -30 C). Compared to no preheat, continuous preheat during an overnight cold soak can reduce the cold-start CO emissions by 20 to 90%.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Dec 01, 1981
Accession Number
ADA112170

Entities

People

  • Harold J. Coutts

Organizations

  • Cold Regions Research and Engineering Laboratory

Tags

Communities of Interest

  • Energy and Power Technologies

DTIC Thesaurus Topics

  • Air Pollution
  • Back Pressure
  • Carbon Monoxide
  • Combustion
  • Combustion Chambers
  • Combustion Products
  • Dielectric Gases
  • Energy Consumption
  • Equations
  • Exhaust Gases
  • Exhaust Systems
  • Gas Meters
  • Heat Energy
  • Internal Combustion Engines
  • Measurement
  • Measuring Instruments
  • Test And Evaluation

Fields of Study

  • Environmental science

Readers

  • Computational Modeling and Simulation
  • Internal Combustion Engine (ICE) Technology.
  • Polar and Arctic Studies