High Energy Density Battery Lithium Thionyl Chloride Improved Reverse Voltage Design.
Abstract
A test program was conducted to demonstrate safety under voltage reversal conditions of the Altus 1400 AH HEDB cell. Eight cells of an improve Anode Grid Design, all cathode (carbon) limited, were forced discharged for 150% of their normal capacity. Minor design variations were tested at 6 amp, 20 C and 12 amp, 0 C with a lithium reference electrode and separate monitoring of current through the internal reverse voltage current shunt feature. There were no ventings and no appreciable increase in cell temperature or internal pressure. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 01, 1981
- Accession Number
- ADA113498
Entities
People
- Andrian E. Zolla