Calibration and Performance of the AEDC/VKF Tunnel C, Mach Number 4, Aerothermal Wind Tunnel

Abstract

The shakedown and calibrated characteristics of the new AEDC Mach Number 4 Aerothermal Wind Tunnel were experimentally identified at several test conditions. The nominal Mach number of the test core as defined by a 30-probe pitot pressure rake varied between nominally 3.95 and 4.0, depending on the test section Reynolds number and stilling chamber temperature. The overall variation in the stilling chamber pressure is nominally 15 to 180 psia, with temperatures from 250 to 1,210 F for an overall Reynolds number range of 0.2 to 8.1 million per foot and true temperature-pressure altitude simulation from 56,000 to 105, 000 ft.