Development Report for the 10 KW Sound Attenuation Program (Preproduction 'F' Kit).

Abstract

This final report covers the program undertaken to develop an acoustic enclosure for the 10 KW 60 Hz GTED Generator Set. The enclosure was designed to meet the performance requirements of category F of MIL-STD-1474. Tests were conducted to determine any detrimental effects of running the gas turbine engine inside of a closed environment. Tests were also conducted to determine the acoustical characteristics of the enclosed package and a comparison done with the standard 10 KW 60 Hz generator set to determine the attenuation provided by the acoustic enclosure.