Isocyanate Monitoring Using N-p-Nitrobenzyl-N-Propylamine Glass Fiber Sampling Tube.

Abstract

N-p-nitrobenzyl-N-propylamine glass fiber sampling tubes were evaluated in the field for detection of Hexamethylene diisocyanate(HDI) during aircraft spray painting and MDI during foam-in-place operations. The tubes, prepared and analyzed according to NIOSH Method P&CAM 326, were satisfactory for HDI monitoring during spray painting, but were inadequate for MDI monitoring under the conditions of the survey.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Aug 01, 1982
Accession Number
ADA119901