High-Temperature Desalination Capability of TFC 1501 Reverse Osmosis Element.

Abstract

This report covers an investigation conducted to evaluate the desalination capability of TFC 1501 reverse osmosis elements when operated with feedwater the temperature of which is substantially above the maximum operating temperature (113 F) specified by the manufacturer. The results of the investigation indicate: (1) The elements were not degraded in desalinating capability following exposure for 400 h to feedwater at approximately 130 F; (2) the production rate of the elements dropped less than 5 percent following exposure for 400 h to water at approximately 130 F and 200 h at 130 F and 600 lb/sq in. (Author)

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jul 01, 1982
Accession Number
ADA121059

Entities

People

  • Haruhiro H. Goto

Tags

Communities of Interest

  • Energy and Power Technologies
  • Ground and Sea Platforms
  • Weapons Technologies

DTIC Thesaurus Topics

  • Air Force
  • Drops
  • Engineering
  • Engineers
  • Flow Rate
  • High Pressure
  • High Temperature
  • Measurement
  • New York
  • Pressure Gages
  • Production
  • Production Rate
  • Reverse Osmosis
  • Standards
  • Test Methods
  • Water
  • Water Purification

Readers

  • Environmental Engineering
  • Materials Science
  • Mathematics or Statistics