Selection and Calibration of Pressure Transducers for Low Pressure Measurement (0.001 psia) in The Tunnel 9 High Altitude Side Force Tests (WTR1365),
Abstract
A study of potential methods for measuring extremely low pressures (0.001 psia) in the NSWC Hypervelocity Wind Tunnel No. 9 was undertaken. Candidate techniques were evaluated in terms of compatibility with wind tunnel models, accuracy, response time, and availability. A detailed calibration was performed on random Microswitch, Model 130 PC transducers to check linearity, hysteresis, sensitivity, and repeatability. The effect of tube length and diameter on the response time of a pressure measuring system was also considered.
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 01, 1982
- Accession Number
- ADA125475
Entities
People
- Mark M. Roberts
Organizations
- Naval Ordnance Laboratory