The Cooling of Printed Circuit Board Mounted Components Using Copper Ladder Heat Conduction to a Cold Wall.
Abstract
This Report describes a series of experimental tests, designed to investigate the cooling of printed circuit board (PCB) mounted dual-in-line (DIL) components within an avionic box using the copper ladder/cold wall technique. Areas of investigation include avionic box orientation, side wall conduction, top plate finning, mixed 'air-wash', avionic power reduction, cooling air temperature reduction, cooling air mass flowrate reduction, cold wall heat pick-up and avionic box insulation. Results were obtained from thermocouple temperature measurements, details of the instrumentation used as well as the thermocouple and component layout within the avionic box are included. The use of an aluminum alloy 'interplate' to cool two adjacent PCBs is also discussed. Results in graphical form are included together with a list of conclusions on the effects of all the major parameters considered.
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 01, 1982
- Accession Number
- ADA129350
Entities
People
- I. C. Dale
Organizations
- Royal Aircraft Establishment