Hypocapnia and Sustained Hypoxia Blunt Ventilation on Arrival at High Altitude
Abstract
Hypoxia at high altitude stimulates ventilation but inhibitory influences limit the ventilatory response. Possible inhibitory influences include hypocapnia and depression of ventilation during sustained hypoxia. Our approach was to compare hypoxia ventilatory responses at low altitude with ventilation at high altitude. In 12 subjects we compared responses at acute (< 10 min) isocapnic hypoxia, acute poikilocapnic (no CO2 added) hypoxia and sustained (30 min) hypoxia in Denver, 1600 M, with ventilation measured on each of 5 days on Pikes Peak, 4300 M. On Pikes Peak day 1 ventilation (VE=10.0 1/min, SaO2-82%) was less than predicted by either acute isocapnic of poikilocapnic tests. However, sustained poikilocapnic hypoxia (SaO2=82%) in Denver yielded ventilation similar to that on Pikes Peak day 1. By Pikes Peak days 4 and 5, end-tidal PCO2, pHa, and arterial oxygen saturation approached planteaus, and ventilation (12.4 1/min) was as predicted by the acute isocapnic test. Thus, the combination of hypocapnia and sustained hypoxia may have blunted the ventilatory increase on Pikes Peak day 1, but apparently not after 4 or 5 days of acclimatization.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 07, 1983
- Accession Number
- ADA129720
Entities
People
- J. K. Alexander
- J. T. Maher
- R. E. Mccullough
- R. F. Grover
- S. Y. Huang
Organizations
- University of Colorado Health