Simplified Thermal Transient Test for Electro Explosive Devices
Abstract
A simplified thermal transient test system for bridgewire-initiated electro explosive devices is described. The method used is that developed by Rosenthal. An automated data recording system and computer analysis of results are included.
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 01, 1983
- Accession Number
- ADA132970
Entities
People
- Wallace E. Voreck
- Yong W. Kwon
Organizations
- United States Army Armament Research, Development and Engineering Center