Source Region EMP Coupling to Long Lines.
Abstract
This report compares the results of several calculational techniques used to evaluate the results of source region EMP coupling to long lines. In particular, approximate transmission line models are compared to more detailed three-dimensional finite-difference techniques for both aerial and buried lines, but substantial differences were seen for aerial lines where time-dependent air conductivity is an important factor.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 01, 1981
- Accession Number
- ADA136817
Entities
People
- D. F. Higgins
- J. P. Wondra
- Scott Smith
- T. A. Tumollilo
- W. A. Radasky