Air Stripping Pilot Study of VOC (Volatile Organic Compounds)-Contaminated Ground Water. Volume 1. General Engineering Aspects.

Abstract

Environmental Science and Engineering, Inc. (ESE) performed a series of test runs in a packed column air stripper to determine performance for removal of four volatile contaminants. Test results were used to determine effect of various conditions such as matrix, contaminant concentration, stripper configuration, and temperature on stripper performance for treating ground water at various Department of the Army installations.