Range-Doppler Moving Target Indicator (MTI) Analysis and Assessment.
Abstract
The concept of a new moving target indicator (MTI) based on the range-doppler coupling properties of chirp, step-chirp, and certain polyphase codes is discussed. The principal feature of the range-doppler coupled MTI is that target blind speeds are eliminated. The polyphase codes must by symmetric for proper operation in a range-doppler coupled MTI. The performance of this MTI is evaluated, and its limitations are identified. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 20, 1984
- Accession Number
- ADA139579
Entities
People
- B. L. Lewis
- F. F. Kretschmer Jr.
- F. L. C. Lin
Organizations
- United States Naval Research Laboratory