Automated Identification, Sizing and Counting of Particulate Contamination Found in Hydraulic Recoil Systems
Abstract
Procedures for the automated identification, sizing, and counting of particulate contamination in hydraulic recoil systems have been developed. The automated system can provide meaningful, accurate data in various formats and a dedicated Automated Particle Analysis system has the potential to provide results quickly to meet production needs on an unattended operating basis. Additional keywords: Hydraulic fluids, Recoil mechanisms, Artillery, Hydraulic recoil mechanism; Scanning electron microscope; Secondary electrons; Backscattered electrons; Characteristic X-rays; Energy dispersive spectrometer; LeMont image analysis System (B-10); Automated particle counting system; Data save; Chemical definition file; Diameter; Gridameter; and Relative intensity classification.
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1984
- Accession Number
- ADA150554
Entities
People
- L. A. Post
- W. D. Mchenry