An Apparatus for Sizing Particulate Matter in Solid Rocket Motors.
Abstract
A light scattering apparatus to measure particle size (D32) in a solid rocket motor was improved. Multiple consecutive scans of two photodiode arrays were accomplished with a pacing circuit and added memory. The device was calibrated using various suspended particle samples and found to make accurate measurements. Addtional keywords: Theses, Data acquisition, Data reduction, Diffraction, Polydispersion, Solid propellants, Computer programs. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 01, 1984
- Accession Number
- ADA151282
Entities
People
- R. K. Harris
Organizations
- Naval Postgraduate School