National Program for Inspection of Non-Federal Dams. Foundry Pond Dam MA 00394, Jones River Basin, Kingston, Massachusetts. Phase I Inspection Report.

Abstract

Foundry Pond Dam is an earth embankment about 210 ft. long with a maximum height of about 15 ft. and an irregular crest which has a minimum width of about 18 ft. The dam is considered small in size with a hazard potential of high. The dam appeared to be in fair condition. There are deficiencies which the owner should engage a professional engineer to check out.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Feb 01, 1980
Accession Number
ADA154489

Entities

Organizations

  • New England District, U.S. Army Corps of Engineers

Tags

Communities of Interest

  • Human Systems

DTIC Thesaurus Topics

  • Concrete
  • Construction
  • Dams
  • Deficiencies
  • Drainage Basins
  • Embankments
  • Engineering
  • Engineers
  • Flood Control
  • Maintenance
  • Massachusetts
  • Materials
  • New England
  • Safety
  • United States
  • Visual Inspection
  • Warning Systems

Readers

  • Facility/Structural Engineering.
  • Riverine Ecology
  • Space/Atmospheric Physics.