National Program for Inspection of Non-Federal Dams. Country Club (MA 00756), Connecticut River Basin, Northampton, Massachusetts. Phase I Inspection Report.

Abstract

The dam is basically comprised of 2 stone masonry vertical faced spillways. The main spillway has a length of 69 ft. and a structural height of 32 ft. The secondary spillway has a length of 30 ft. and a height of about 9 ft. The visual inspection did not disclose any findings that indicate an immediate unsafe condition. The size classification is small with a hazard potential of significant. Due to the lack of drawdown capabilities, the dam is considered in fair condition. (Author).

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jun 01, 1979
Accession Number
ADA155534

Entities

Organizations

  • New England District, U.S. Army Corps of Engineers

Tags

Communities of Interest

  • Weapons Technologies

DTIC Thesaurus Topics

  • Concrete
  • Construction
  • Dams
  • Embankments
  • Engineering
  • Engineers
  • Flood Control
  • Geotechnical Engineering
  • Inspection
  • Massachusetts
  • Materials
  • New England
  • Safety
  • Spillways
  • United States
  • Visual Inspection
  • Warning Systems

Readers

  • Hydrologic Risk Analysis and Mitigation.
  • Systems Analysis and Design