National Program for Inspection of Non-Federal Dams. Lake Clara Dam (VT 00011) Connecticut River Basin, Whitingham, Vermont. Phase I Inspection Report.

Abstract

The dam is an earthfill dam about 370 ft. long and 31 ft. high. There are no operable appurtenant structures. The dam is judged to be in fair to poor condition. The test flood falls between the 1/2 PMF and the PMF. There are various significant conditions which should be corrected. Alternatively, the lake should be lowered to a safe level until such time as repairs can be made.