Prestressed Concrete Fender Piles - Analysis and Final Test Pile Details.
Abstract
Using prior test results this study refined an analytical model investigating various alternatives to optimize concrete pile design for Navy piers. Parameters evaluated were: size, prestressing force, load application, ductility, placement of reinforcement, and concrete strength. It was demonstrated that prestressed concrete piles will outperform steel and timber piles in a pile-for-pile energy comparison and are more cost-effective. Recommendations are made for a final test program. Keywords: Fenders, Piles, and Fender piles.
Document Details
- Document Type
- Technical Report
- Publication Date
- May 01, 1986
- Accession Number
- ADA169516