Underwater Purging Procedures for the Draeger LAR V UBA (Underwater Breathing Apparatus).
Abstract
The U.S. Navy has identified a need to switch to the Draeger LAR V closed-circuit oxygen Underwater Breathing Apparatus from open-circuit air while underwater. The revised purge procedure described in NEDU Report 5-84 and subsequently approved for fleet use was tested only at 1 ATA. This study was carried out to develop a purge procedure suitable for use underwater. Three different purge procedures were tested. The incluence of diver position in the water during the procedure and the type of open circuit air facemask regulator configuration used prior to switching to the LAR V were also examined.
Document Details
- Document Type
- Technical Report
- Publication Date
- May 01, 1986
- Accession Number
- ADA170822
Entities
People
- F. K. Butler Jr.
Organizations
- United States Navy Experimental Diving Unit