Defect Investigation of Cartridge Illuminating 1-1/2 Inch.
Abstract
The bulging of metal ammunition boxes containing 1-1/2 illuminating Flare Cartridges has been investigated. The defect occurred during storage of flares manufactured in 1976-78 and was found to be due to the entry of moisture into the magnesium based flare composition resulting in the generation of hydrogen. The stores were so adversely affected that MRL recommended that they be destroyed.
Document Details
- Document Type
- Technical Report
- Publication Date
- Apr 01, 1986
- Accession Number
- ADA173717
Entities
People
- M. A. Wilson
- R. Bird
Organizations
- Defence Science and Technology Group