Defect Investigation of Cartridge Illuminating 1-1/2 Inch.

Abstract

The bulging of metal ammunition boxes containing 1-1/2 illuminating Flare Cartridges has been investigated. The defect occurred during storage of flares manufactured in 1976-78 and was found to be due to the entry of moisture into the magnesium based flare composition resulting in the generation of hydrogen. The stores were so adversely affected that MRL recommended that they be destroyed.