An Automatic Crack Measuring System Using the Direct-Current Potential-Difference Method,
Abstract
This report describes the development of a computer controlled direct-current potential-difference crack measuring system and its application to obtain crack growth rate data from centre-cracked-tension specimens. Details of the hardware and the software are included and the method and results fo the calibration for this type of specimen are given. Keywords: Direct current; Crack measurement; Computer applications; Crack propagation; Electric potential. (Australia)