MS-116A High Voltage Protection unit.

Abstract

Included in this report are the status of Mechanical/Electrical Design, Prototype Production, Testing (both Preliminary Design and Finished Prototype), and System Safety Analysis. It is the intention of this reporter to provide a succinct synopsis on each of the afore mentioned scopes. The synopsis will cover all aspects since the commencement of development until the present day. The Mechanical/Electrical design of the HVPU was conceived after consideration of the operating conditions experienced and the function to be accomplished. Many possible designs were considered, weighing the disadvantages and advantages of each to achieve the optimum result. Preliminary testing played a vital role in the Mechanical/Electrical Design process. The HVPU was developed by close comparative testing with a conventional MS-116A Unit so that the basic characteristics were as similar as possible.