An Absolute Scanning (NF (Alpha (1Delta)) and (NF (b(1Epsilon)) Diagnostic for the N2F4 + H2 System.

Abstract

The N2F4 + H2 system is of interest for production of NF(a1 delta) as an energy transfer species. Past studies have been plagued with the difficult NF (a1 delta) quantitative measurement due to interferences from the close-lying N2(B) and HF peaks. This paper deals with the development of a scanning diagnostic to determine concentrations of NF(a1 delta) and NF(b1 sigma) in the N2F4 + H2 system and quantitative measurement of interferences with the diagnostic signal. The diagnostic was then applied to a functioning high-pressure, high-temperature system.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jun 01, 1987
Accession Number
ADA185455

Entities

People

  • Y. D. Jones

Organizations

  • Air Force Research Laboratory

Tags

Communities of Interest

  • Energy and Power Technologies
  • Weapons Technologies

DTIC Thesaurus Topics

  • Air Force
  • Calibration
  • Classification
  • Detection
  • Detectors
  • Emission
  • Energy Transfer
  • High Density
  • High Pressure
  • High Temperature
  • Measurement
  • Molecules
  • Monochromators
  • Photographs
  • Production
  • Security
  • Spectra

Readers

  • Analytical Mechanics
  • Medical Imaging.
  • Neurological Diseases/Conditions/Disorders