Advanced Line Contactor.
Abstract
A breadboard and two prototype Advanced Line Contactors (Hybrid mechanical contactor and transistor switch) have been fabricated and successfully tested. These units are able to turn-on, carry, and turn-off continuous load currents between zero and 400 Adc at 270 Vdc. For non-continuous overload currents of 600 Adc, they are able to turn-on turn-off three times in two minutes. Keywords: Advanced line contactor, Electromagnetic relay, High current (600 Adc) 270 Vdc switching, Hybrid contactor, Mechanical contactor, Parallel transistors for 270 Vdc, 600 Amps switching operation, Solid-state switch, Transistor power switching.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 03, 1986
- Accession Number
- ADA187194
Entities
People
- C. B. Hassan
Organizations
- Lockheed Martin