Dynamic Test of a Corrugated Steel Keyworker Blast Shelter Misty Picture
Abstract
The 18-man blast shelter was tested dynamically on May 14, 1987 in the MISTY PICTURE event at White Sands Missile Range, NM. The main section of the shelter was fabricated from a 9-foot-diameter, 27.5-foot-long section of 10- gage, galvanized, corrugated steel culvert. The shelter included a vertical entryway and air intake and exhaust stacks. The shelter design was found to be conservative during a previous 50-psi validation test, and some constructibility problems were encountered with the entryway-to-shelter connections. This test was conducted to validate the modifications made to the shelter design. The modifications were made to reduce construction costs and improve constructibility. Primary modifications included: replacing the stiffened endwalls with lighter weight unstiffened plates, connecting the entryway to an endwall rather than to the main section of the shelter, and the inclusion of an emergency exit. The structure was located at the anticipated 200-psi peak overpressure level. Posttest inspection revealed that the main section of the shelter suffered very little damage during the test. Due to the failure of the emergency exit cover plate, it was necessary to determine if enough pressure entered the shelter to affect its structural response. This test also investigated the shock environment inside the shelter. Keywords: Blast effects; Nuclear blast shelter; Shallow-buried structures; Soil-structure interaction; Structural design; Dynamic tests; Dynamic response; Nuclear explosion testing; Nuclear explosion damage.
Document Details
- Document Type
- Technical Report
- Publication Date
- Nov 01, 1987
- Accession Number
- ADA190607
Entities
People
- Aaron L. Harris
- Randy L. Holmes
- Thomas R. Slawson