Analysis of Debris from Accelerated Life Test of the Hughes Five-Year Vuilleumier Cryocooler.
Abstract
Unit S3 of the Hughes Vuilleumier (VM) Cryocooler Program has undergone accelerated life testing at twice the service speed expected in a normal unit. Debris samples were obtained from all areas of the cooler; samples of the regenerator balls were collected from the second and third stages only. The debris has been identified by an investigative analysis using the analytical techniques of X-ray diffraction, IMMA, and SEM/EDXS. Most of the particulates contain a combination of Iron, Chromium, and Nickel or Molybdenum Niobium compounds.
Document Details
- Document Type
- Technical Report
- Publication Date
- May 29, 1987
- Accession Number
- ADA193101
Entities
People
- D. C. Cranmer
- E. J. Watts
Organizations
- The Aerospace Corporation