Impedance Studies of the Cell Ag/AgI/Ag Beta Alumina/AgI/Ag
Abstract
The construction of the cell Ag/AgI/Ag beta alumina/AgI/Ag is described. The impedance of this cell was measured between .001 and 10000 Hz at temperatures between 20 and 550 C. At temperatures below 100 C the cell impedance is determined to a large extent by the bulk resistance of the AgI layer and to a smaller extent by the impedance of the interface Ag/Agi. At temperatures between 160 and 350 C the impedance is controlled by the bulk resistance of the Ag beta alumina and an impedance due to contact problems between Ag and AgI. The bulk resistance of the beta' alumina becomes predominant between 350 and 550 C. A hindrance due to the transfer of silver ions from AgI to Ag beta' alumina was not observable in the whole temperature range.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 01, 1988
- Accession Number
- ADA198254
Entities
People
- H. Drstak
- M. Maly-schreiber
- M. W. Breiter