Study of SSIN (Single Stage Interconnection Networks) Parallel Processing Interconnection Networks
Abstract
The increase in dynamic average path length (DAPL- with network size is moderate while it is significantly less than log(2)N, the number of stages needed in a MIN. The best performance in the case of no fault and single fault, is obtained for the modified Omega and the Zeta SSINs. Keywords include: Interconnection networks, Switches, and Parallel processing networks.
Document Details
- Document Type
- Technical Report
- Publication Date
- Oct 31, 1988
- Accession Number
- ADA202023
Entities
People
- Dharma P. Agrawal
Organizations
- North Carolina State University