Shielding Effectiveness Measurement of the SCI Shielded Enclosure
Abstract
The attenuation of the SCI shielded enclosure used to perform Electromagnetic Interference Tests in plant was measured using the two antenna methods outlined in MIL-STD-285. The measurement frequency band was 100 kHz to 200 MHz.
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 01, 1987
- Accession Number
- ADA202659
Entities
People
- Robert A. Snead
Organizations
- United States Army Aviation and Missile Command