The Effects of High-Altitude Electromagnetic Pulse (HEMP) on the Northern Telecom Inc. DMS-100 (Trademark) Switch. Volume 1. Executive Summary

Abstract

This report is part of a three volume set that presents the results of simulated High Altitude Electromagnetic pulse (HEMP) testing of a DMS-100 switching system. This volume presents a brief discussion of the test events and the test results, and summarizes the conclusions and recommendations of the test program. Volume II is a detailed description of the test procedures, the test results, and the mitigation alternatives evaluated. Volume II also presents a discussion of the conclusions and recommendations of the program. Volume III describes the post test analysis of the measured electromagnetic fields and induced transients. Volume III also includes a comparison of the characteristic attributes of the various simulator environments.