Hydrocode Modelling of the MISAR Anti-Tank Mine

Abstract

Version 121 of the HULL code was used to predict the properties of the explosively-formed copper penetrator from the MISAR anti-tank mine. The code was run in pure Lagrange mode. Full HULL inputs are listed. The Lagrange rezoner for HULL was de-bugged, and a change deck to fix the rezoner is included.