J-Resistance Curves of Aluminum Specimens Using Moire Interferometry
Abstract
Errors involved in using the approximate J evaluation procedure are evaluated by comparing the resistance curves of large 2024-0 and 5052-H32 aluminum, single edge cracked, cruciform specimens under uniaxial and biaxial loadings with those obtained by an exact procedure. This comparative study shows that under uniaxial loading, the J resistance curves obtained by the approximate procedure are within six percent of those obtained by the exact procedure. For the biaxial loading, however, the difference is about eighteen percent. The specimen size and geometry dependence of the J resistance curves of 2023-0 and 5052-H32 aluminum specimens are also discussed. Aluminum.
Document Details
- Document Type
- Technical Report
- Publication Date
- Apr 01, 1989
- Accession Number
- ADA208239
Entities
People
- Albert S. Kobayashi
- B. S. Kang
- M. S. Dadkhah
Organizations
- University of Washington