Cold Tests of Quasi-Optical Gyrotron Resonators
Abstract
Cold test are performed on a number of quasi-optical gyrotron resonators at 94 and 120 GHz to determine the variation of cavity Q with mirror separation. The separation between the resonator mirrors is varied between 15 and 35 cm, with measured quality factors ranging from 10,000 to 100,000. Good agreement is obtained between the measured data and values calculated from scalar diffraction theory. The effect of misaligning the mirrors is also examines experimentally. Keywords: Quasioptical gyrotron; Cold test; Quality factor; Open resonator; Scalar diffraction theory.
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 07, 1989
- Accession Number
- ADA212707
Entities
People
- Arne W. Fliflet
- R. P. Fischer
- T. A. Hargreaves
Organizations
- United States Naval Research Laboratory