Monitoring Nitrogen Purity by Gas Chromatography
Abstract
A method had to be devised to check the purity of nitrogen to determine compliance with military specification BB-N-411C. A gas chromatographic technique using Flame Ionization Detector (FID) and Thermal Conductivity Detector (TCD) was developed for routine monitoring of nitrogen. An easy to follow step-by-step instruction is provided to analyze contaminants (parts per million) and to determine purity of nitrogen (percent by volume). Keywords: Gas chromatography, Flame ionization, Thermal conductivity; Purity analysis.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 06, 1987
- Accession Number
- ADA213577
Entities
People
- A. Varma
- C. R. Oprandi
- J. F. Danovich
Organizations
- Naval Air Warfare Center Warminster