Acoustic Qualification of an Anechoic Chamber
Abstract
The aim of the work was to determine the working space and frequency range limits of an anechoic sound chamber for accurate measurements of source sound power and directivity. This was achieved by following guidelines in British Standard 4196 and noting the decrease of measured sound pressure levels with increasing distance from the source. Results indicated that the chamber tested in this work was suitable for measurements within 1.5 dB across a frequency range of 125 Hz to 20 kHz so long as microphones are placed sufficiently far from the source and chamber walls. The characteristics of certain source sound fields may lead to an increase in the lower limiting frequency however. Keywords: Anechoic chambers; Laboratory equipment.
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1989
- Accession Number
- ADA217159
Entities
People
- D. J. Hendy
Organizations
- Royal Aircraft Establishment