Users Guide for the Conversion of Navy Paint Spray Booth Particulate Emission Control Systems from Wet to Dry Operation
Abstract
This guide provides users instructions and cost evaluation information for converting the water curtain particulate emission control system currently used on many Navy painting facilities to dry filter operation. Engineering and logistical issues are addressed, and example design plans are provided. construction and operating permit requirements mandated by regulatory agencies, such as air pollution control districts and fire departments, are discussed. Cost estimates that may be used to perform comprehensive cost evaluation analyses are provided. In addition, sample calculations that illustrate how to use the cost data are included. Keywords: Paint booths, Painting wastes, Painting wastewater, Particulate emission control (PEC), PEC conversion.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 01, 1990
- Accession Number
- ADA224737
Entities
People
- Darrel Tate
- Jacqueline Ayer
Organizations
- Naval Facilities Engineering Service Center