Continuous Water Monitoring System

Abstract

This report details the activities of a Phase I Small Business Innovation Research contract with Arnold Engineering Development Center, Air Force System Command, Arnold Air Force Base, Tennessee, to develop a system to monitor return cooling water flow from AEDC to Woods Reservoir. An alarm would be provided to signal when determined levels of selected impurities are exceeded. The work undertaken was the design, prototype construction, and testing of membrane interfaces that allowed gases, but not water to permeate. The gases were then analyzed with a quadruple mass spectrometer.