MIL-STD-398 Explosive Test of Barricade for Volcano MOPMS Cartridge Assembly
Abstract
This agency was tasked to provide MIL-STD-398 instrumentation services for measuring blast overpressure and thermal flux of the barricade for Volcano MOPMS Pressure Cartridge Assembly. The barricade shields operators from a quantity of explosive material used as a filler for the pressure cartridge. A maximum credible incident (MCI) was identified by LSAAP and approved by U.S. Army Material Command, Field Safety Activity (AMCFSA), Charlestown, IN. Based on this criteria, two blast pressure gages were placed at operator positions in front of and at the side of the barricade. thermal flux gages were also placed at the same positions of the blast overpressure gages. The test charge was functioned, blast pressure and thermal flux recorded. Blast overpressure levels were too low in amplitude to be recorded. Thermal flux was recorded and radiation level was well below the exposure limits of MIL-STD-398.
Document Details
- Document Type
- Technical Report
- Publication Date
- Nov 01, 1989
- Accession Number
- ADA240916
Entities
People
- A. C. Mcintosh
Organizations
- Defense Ammunition Center