Guide for Evaluating 12 Inch Substantial Dividing Walls (SDWs) to Provide Protection from Remote Operation. Volume 2
Abstract
This report provides installations with procedures to relate Net Explosive Weights (NEWs) to combinations of intervening 12-inch Substantial Dividing Walls (SDWs) to provide protection to personnel from remote operations where an accidental detonation is the hazard. Protection to be Provided is IAW DoD and Army policy: 2.3 psi maximum overpressure exposure and no hazardous fragments. The report consists of two Volumes. Volume I is a how to guide for installation use; Volume II is the rationale (calculations, etc) behind the Volume 1. Protection from thermal effects from flash fires, deflagrations. etc. is not addressed in the Guide. Remote operations, Substantial dividing walls, Operator protection, Blast protection, Fragments, Accidental detonations.
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 01, 1991
- Accession Number
- ADA250252
Entities
People
- Adib R. Farsoun
Organizations
- United States Army Corps of Engineers