MIL-STD-398 Test of Barricade for M82 Primer, Drawing No. EC-11686
Abstract
The U.S. Army Defense Ammunition Center and School (USADACS) was tasked by Lone Star Army Ammunition Plant (LSAAP), Texarkana, TX to provide MIL- STD-398, Military Standard Shields, Operational for Ammunition Operations, Criteria for Design of and Tests for Acceptance, instrumentation services for measuring blast overpressure and thermal flux produced by several charges of Class 3 black powder constrained to function high order. Two amounts of powder were used, 1.25 and 1.875 pounds. Blast overpressure and thermal flux gages were placed at the operator's position and at a possible transient position around the barricade. All test charges resulted in blast overpressure in excess of 5.0 psi reflected, schrapnel production. Thermal flux was at a minimum. As a result, the barricade for the M82 primer did not satisfy the requirements of MIL-STD- 398, Military Standard Shields, Operational for Ammunition Operations, Criteria for Design of and Tests for Acceptance, or the requirements of AMCR 385-100 for energetic materiel.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 01, 1991
- Accession Number
- ADA256261
Entities
People
- A. C. Mcintosh
Organizations
- Defense Ammunition Center