Optical Fibre Fabry-Perot Interferometers for Calorimetric Heat Transfer Gauges
Abstract
A heat flux measurement system comprising a laser diode, a single mode optical fibre interferometer and passive optical fibre components has been constructed. The system has been designed for use in transient flow wind tunnels and has a resolution of 1 kWm/sq meter, a dynamic range of 20 MW m/sq meter and bandwidth > 100 kHz. Heat flux measurements have been made with the system on the endwall of a cascade of stator blades. Optical fibre, Heat flux.
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 01, 1992
- Accession Number
- ADA262824
Entities
People
- I. W. Matthews
- J. D. Jones
- J. S. Barton
- K. S. Chana
- S. R. Kidd