Composite Unit Accelerated Life Test of the High Gain Array
Abstract
This report documents the composite unit life testing (CUALT) of a 20-element hydrophone array. The array was subjected to a CUALT which simulated five years of service life. After CUALT was completed, an autopsy was performed on the array to determine failure modes and mechanisms. This report also documents array design, mission profile, CUALT schedule and measurement data, autopsy results, and failure analysis.... Accelerated life testing, Hydrophone array, Hydrophone reliability.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 08, 1993
- Accession Number
- ADA263265
Entities
People
- A. V. Bray
- S. C. Liberty
- S. L. Arnett