Composite Unit Accelerated Life Test of the High Gain Array

Abstract

This report documents the composite unit life testing (CUALT) of a 20-element hydrophone array. The array was subjected to a CUALT which simulated five years of service life. After CUALT was completed, an autopsy was performed on the array to determine failure modes and mechanisms. This report also documents array design, mission profile, CUALT schedule and measurement data, autopsy results, and failure analysis.... Accelerated life testing, Hydrophone array, Hydrophone reliability.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jan 08, 1993
Accession Number
ADA263265

Entities

People

  • A. V. Bray
  • S. C. Liberty
  • S. L. Arnett

Tags

Communities of Interest

  • Advanced Electronics
  • Biomedical

DTIC Thesaurus Topics

  • Circuit Boards
  • Composite Materials
  • Engineering
  • Failure Analysis
  • Failure Mode And Effect Analysis
  • Gain
  • High Gain
  • Hydrophones
  • Life Tests
  • Long Life
  • Materials
  • Measurement
  • Printed Circuit Boards
  • Printed Circuits
  • Reliability
  • Test And Evaluation
  • Transducers

Fields of Study

  • Engineering

Readers

  • Acoustical Oceanography.
  • Software Engineering