Laboratory Comparisons of Acoustic and Optical Sensors for Microbubble Measurement
Abstract
This paper presents the results of a recent comparison between three microbubble size spectrum measurement systems. These systems are the light- scattering bubble counter, the photographic bubble-imaging system, and the acoustic resonator array. Good agreement was formed among these three systems over the bubble size range appropriate for each system. Microbubbles, Wave breaking.
Document Details
- Document Type
- Technical Report
- Publication Date
- Feb 01, 1994
- Accession Number
- ADA277218
Entities
People
- Douglas Todoroff
- John Cartmill
- Ming Y. Su
Organizations
- United States Naval Research Laboratory