Treatability Study in Support of Intrinsic Remediation for the Jet Fuel Transfer Line Southwest of Building 412 and the POL Yard. Volume 1: Text. Wisconsin Air National Guard at Truax Field, Madison, Wisconsin
Abstract
This report presents the results of a treatability study (TS) performed by Parsons Engineering Science, Inc. (Parsons ES) at Truax Field Air National Guard Base, Wisconsin to evaluate the use of intrinsic remediation (natural attenuation) with long-term monitoring (LTM) as a remedial option for dissolved benzene, toluene, ethylbenzene, and xylene (BTEX) contamination in the shallow saturated zone in the vicinity of the former jet fuel transfer line southwest of Building 412 and the petroleum, oils, and lubricants (POL) yard (the site). Soil and ground water contamination is documented for the site, with contamination being present in the aqueous (i.e., dissolved) and gaseous phases and as residual light nonaqueous-phase liquid (LNAPL) within the aquifer matrix. There is no evidence of mobile LNAPL (free product) at this site. This study focused on the impact of dissolved bTEX on the shallow ground water system at the site. Site history and the results of soil and ground water investigations conducted previously are also summarized in this report