Evaluation of Miniburn Test Data for the SQI, Support of Interim Operations.

Abstract

The purpose of this report is to analyze the results obtained during test burns runs ('miniburns') of Basin F liquid at the Rocky Mountain Arsenal Submerged Quench Incinerator (SQI). Specifically, the analysis focuses on the following issues: The nature and level of measured release products, in comparison to those predicted. The actual ('as-built') operating conditions, in comparison to the design specifications. The estimated risk to human health based on the measured emission rates, in comparison to those based on predicted emission rates. The predicted emissions, design parameters and human health risks were presented originally in the Final Draft Human Health Risk Assessment (WESTON, 1991). jg p6