Operation Tumbler-Snapper, Nevada Proving Grounds, April-June 1952, Project 12.1 - Bhangmeter Mod II
Abstract
The Mod II Bhangmeter used for Operation Tumbler-Snapper was developed for Operation Buster-Jangle. It is a device for determining the yield of an atomic explosion photoelectrically. A measure of the visible radiation as a function of time provides a basis for scaling the device under measurement against previously detonated weapons of known yield. The evaluation of this instrument can be traced through previous reports such as Air Drop Instrumentation, Bhangmeter.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 01, 1953
- Accession Number
- ADA304446
Entities
People
- Herbert E. Grier
Organizations
- EG&G