Hydrolytic Stability of Adiprene L-100 and Alternate Materials.

Abstract

Adiprene L-1OO/MOCA and four potential alternate materials were tested after accelerated aging conditions in a steam autoclave. Test methods included: mechanical spectrometry, thermomechanical analysis, infrared analysis, solubility in tetrahydrofuran, and gel permeation chromatrography. Conathane EN-7 was the most resistant to accelerated attack by steam hydrolysis and showed little change in properties after 50 hours exposure.