Postflight Optical Evaluation of the Right-Hand and Left-Hand Windows of Gemini Missions IV, V, VI, and VII.

Abstract

Transmission and relative resolution measurements were made before cleaning, and transmission, schlieren, relative resolution, and interferometric measurements were made after cleaning, on the right-hand and left-hand windows of Gemini spacecraft G-IV to G-VII. Chemical analyses of the contamination cleaned from the windows show that the primary constituent is amorphous silica.