Reduction of Data from Heat-Flux Gauges - A Documentation of the MIT ACQ Code and an Adaptation to Single-Sided Gauges.
Abstract
The Massachusetts Institute of Technology (MIT) ACQ code for the reduction of data from heat flux gauges has been adapted for use in the Turbine Research Facility (TRF) Data Acquisition System (DAS). MIT developed the code to determine the fluctuating (AC) heat flux component from their double sided gauges. Here the code is adapted to single sided gauges with the capability to determine both mean (DC) and fluctuating (AC) heat flux levels. The code is verified using several test cases and thoroughly documented.
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 01, 1994
- Accession Number
- ADA315473
Entities
People
- G. Guenette
- J. Moselle
- M. Dunn
- M. M. Weaver
Organizations
- Calspan